Low Voltage rubber Flexible Cable for reeling Applications
Flexible cable designed for high mechanical stresses, especially for applications with frequent winding and unwinding with concurrent tensile and torsion stress. The cable is used for conveyors, container cranes, harbour cranes, building machinery, handling machines in mining and tunneling equipment. For use in wet or dry conditions, in industrial units, in underground and open-cast mining, in explosion-risk areas. Excellent tear, impact and abrasion resistant outer sheath
Design Features
Conductors | Annealed flexible stranded tinned copper conductor class 5 acc. to IEC 60228 |
Separator | If needed a suitable tape separator between the conductor and insulation |
Insulation | EPDM rubber, halogen-free, lead-free compound, type 3GI3 acc. to DIN VDE 0207/20 |
Circuit Identification | Colour coding of power conductors compliant to HD 308, DIN VDE 0293- 308 -J version: 3 – core: Green-yellow, blue, brown 4 – core: Green-yellow, brown, black, grey or greenyellow, blue, brown, black 5 – core: Green-yellow, blue, brown black, grey Above 5 cores: Green-yellow, other cores black with white numbering -O version: 3 – core: Brown, black, grey or blue, brown, black 4 – core: Blue, brown, black, grey 5 – core: Blue, brown, black, grey, black Above 5 cores: Black with white numbering |
Inner sheath | A synthetic thermosetting compound type Gm1b acc. to DIN VDE 0207/21, Black |
Anti-torsion braid | Braid of polyamide threads between inner and outer sheath |
Outer sheath | Special synthetic thermosetting compound, type 5GM3 acc. to DIN VDE 0207/21, Black |
Features
Rated voltage | 0.6/1 kV |
Max operating voltage | 1.2 kV |
AC test voltage | 3 kV |
Current carrying capacity | DIN VDE 0298-4 |
Max conductor operating temperature | +90°C |
Max. conductor temperature during short circuit | +250°C |
Minimum ambient temperature for fixed installation | -40°C |
Minimum ambient temperature for mobile installation | -25°C |
Oil resistance | PN-EN 60811-404, IEC 60811-404 |
UV resistance | UL 2556, ISO 4892-2 |
Twist limits | 25˚/m |
Ozone resistant | PN-ISO 1431-1 |
Travel speed | 180 m/min |
Tensile load | 20 N/mm2 |
Flame propagation | PN-EN 60332-1-2, IEC 60332-1-2 |