Position Switch Module

UO-EM-ERC

System solution u-one-lwl

Output signals / Interfaces

  • Monitor overspeeds and underspeeds
  • Relay contacts / switching outputs: 2 programmable, 1 diagnostics
  • Switching capacity up to 250 V AC/DC and 0.5 A
  • Options: SIL 2 / PL d certification (UO-EM-EGS41)

The Position Monitor

The electronic position switch with six programmable switching outputs (each with one on and one off switching points) are available with numerous functions. The number of bits for multiturn operations, singleturn or multiturn ranges as well as the switching range inputs with invert option are programmable. They determine hysteresis values, counting direction and the unit, identification, last change and conversion factor.

Specifications

Supply voltage12-30 VDC
Dimensions99.5 x 45 x 114.5 mm (modular electronics housing for DIN rail)
Signal outputs/Interfaces-6 programmable position switches (changeover contact 250 V / 0.5 A AC/DC)
-Status output: 1 potential-free relay output (NC contact 250 V / 0.5 A AC/DC)
-Preset: 1 optorelay (preset input 12…30 V / 5 mA DC and handshake output (40 V / 0.1 A DC)
-Programmable functions via decoder module UO-EM-D2 (ERCPro – software): Operating range inputs with inversion option, hysteresis value, count direction, unit, identification, last alteration (automatic input), conversion factor.
-LED indicator: Power / Status / Relay status
Electrical connection-Screw terminals to connect switches
-Series connectors to preceding and following modules (internal bus connection)
Device temperature range-25 °C to +70 °C
Degree of protectionIP20 (switchboard installation)
Device optionsCombines with other modules belonging to the U-ONE System
Special features and certificates-UL/CSA